店舗・オフィス用カスタムエアコン2014年3月
157/204

仕様 天井吊形P112~P140形P160形スマートエコRスーパーパワーエコキューブP112~P160形P40~P80形P224・P280形P224・P280形--------------------主5分5主5分5主+分30主+分30主5分5主5分5主5分5主5分5主5分5主5分50.9100.9101.091.091.211.211.301.301.58 1.58 1.922.753.443.815.815.987.077.292.750.3400.3400.3600.3600.3800.3800.4550.4550.4900.4900.6650.9051.101.272.372.542.752.970.9051.491.491.531.531.321.321.931.931.801.802.762.764.426.136.877.048.758.972.769.606.909.606.909.606.9014.28.4014.28.4010.115.317.624.628.038.015.15.062.926.063.506.723.887.224.178.685.015.908.8210.711.717.818.421.522.28.82909090909090909091919490939494959020202020202020202020202030303030主+分20●室内外渡り配線:室外~室内…3線、室内~室内…2線 ●リモコン渡り配線:主機~リモコン…2線、主機~従機…2線 ●ケースヒーター:P224・P280形…(0.026+0.026)kW ●ドレン配管:VP20 (トリプル…×3 ダブルツイン…×4)●室内外渡り配線:室外~室内…3線、室内~室内…2線 ●リモコン渡り配線:主機~リモコン…2線、主機~従機…2線 ●ドレン配管:VP20 (ツイン…×2)--------------------内0.139×2外0.600内0.139×2外0.600内0.094×3外0.100×2内①0.094内②0.094×2外0.100×2内0.094×3外0.600内①0.139内②0.094×2外0.600内①0.139内②0.094×2外0.600内①0.139×2内②0.094外0.600内0.094×4外0.600内0.094×4外0.60044・38・3244・41・3537・35・28①41・36・29②36・34・2841・36・29①44・38・32②37・35・28①44・41・35②41・36・29①44・38・32②37・35・2837・35・2841・36・2956/5756/5749/5149/5156/5756/5756/5756/5756/5756/57内(9.5/15.9)×2外(9.5/25.4内(9.5/15.9)×2外(12.7/25.4内(6.4/12.7)×3外(9.5/15.9内①(9.5/15.9内②(6.4/12.7)×2外9.5/15.9内(9.5/15.9)×3外(9.5/25.4内①(9.5/15.9内②(6.4/12.7)×2外9.5/25.4内①(9.5/15.9内②(9.5/15.9)×2外12.7/25.4内①(9.5/15.9)×2内②(6.4/12.7外12.7/25.4内(6.4/12.7)×4外(9.5/25.4内(9.5/15.9)×4外(12.7/25.414.014.05.55.514.014.014.014.014.014.038.038.014.014.038.038.038.038.038.038.0606030306060606060601.8×22.7×23.13.11.8×21.8×22.7×22.7×21.8×22.7×2100100505010010010010010010050/3050/3030/3030/3050/3050/3050/3050/3050/3050/30-----------------内0.094外0.043内0.094外0.043内0.094外0.043内0.094外0.043内0.094外0.043内0.094外0.043内0.094外0.043内0.094外0.043内0.094外0.043内0.094外0.043内0.094外0.043内0.139外0.063内0.139外0.100内0.139外0.100×2内0.16×2外0.100×2内0.16+0.19外0.100×2内0.094×2外0.063内31.0×2外200.0内31.0×2外200.0内15.0×3外103.0内①23.5内②14.0×2外103.0内23.5×3外200.0内①31.0内②15.0×2外200.0内①31.0内②23.5×2外200.0内①31.0×2内②15.0外200.0内15.0×4外200.0内23.5×4外200.0内14.0外39.0内14.0外39.0内14.0外39.0内14.0外39.0内15.0外39.0内15.0外39.0内15.0外40.0内15.0外40.0内19.5外40.0内19.5外40.0内23.5外45.0内31.0外56.7内31.0外70.0内34.0外103.0内58.0外133.3内70.0外150.0内15.0×2外56.736・34・2836・34・2836・34・2836・34・2837・35・2837・35・2837・35・2837・35・2837・35・2837・35・2841・36・2944・38・3244・41・3546・42・3653・-・5055・-・5237・35・2846/4746/4746/4746/4746/4746/4747/4847/4847/4847/4848/5250/5452/5449/5156/575750/54 6.4/12.7 6.4/12.7 6.4/12.7 6.4/12.7 6.4/12.7 6.4/12.7 6.4/12.7 6.4/12.7 6.4/12.7 6.4/12.7 9.5/15.9 9.5/15.9 9.5/15.9 9.5/15.9 9.5/25.4 12.7/25.4内(6.4/12.7)×2外(9.5/15.93030303030303030303030505075707050φ2.0φ1.6φ2.0φ1.6φ2.0φ1.63.5φ1.63.5φ1.6φ2.05.55.55.58.014.05.530/3030/3030/3030/3030/3030/3030/3030/3030/3030/3030/3030/3030/3030/3030/3030/3030/30-φ2.0-φ2.0-φ2.0-5.5-5.55.514.014.014.022.022.014.01515151515151515151515203030405020-----------------0.750.750.750.750.750.751.11.11.11.11.62.53.03.14.25.52.5----------------------------------6.8110.45.245.246.816.8110.410.46.8110.42.002.731.361.362.002.002.732.732.002.736.018.354.644.646.016.018.358.356.018.351.922.491.321.321.921.922.492.491.922.496.709.536.356.356.706.709.539.536.709.5321.4 31.9 16.1 16.1 21.4 21.4 31.9 31.9 21.4 31.9 18.725.914.214.218.718.725.925.918.725.940.547.924.624.740.140.347.948.240.247.992949494929294949294939394949393939393931.201.201.471.471.651.651.951.952.152.152.794.215.285.458.078.2411.311.54.210.3900.3900.4300.4300.4400.4400.6500.6500.5700.5700.8501.131.401.432.702.873.293.511.136.673.858.174.729.075.2310.66.1211.76.758.5712.916.216.724.825.334.334.912.99090909091919292929294949494949594B224B280C160E160C224E224E280D280F224F280セット名 称運転音 (dB(A))消 費 電 力 (kW)力 率(%)冷媒配管(φmm) 最小電線 (φmm、mm2)ブレーカー(A)最大落差室外上/下(m)冷 房暖 房定格最大冷/暖液側/ガス側室 外20m以下50m以下25m以下室外中間低温冷房暖房冷暖中間定格室 内急・強・弱運 転 電 流(A)送風機出 力(kW)標準風量(m3/min)始動電流圧縮機出力(kW)補助H(kW)最大長さ(m)チャージレス(m)電 気 特 性機 外 配 線室外H室内H室内※3(A)※1※2A40JA40A45JA45A50JA50A56JA56A63JA63A80A112A140A160A224A280B112セット名 称運転音 (dB(A))消 費 電 力 (kW)力 率(%)冷媒配管(φmm) 最小電線 (φmm、mm2)ブレーカー(A)最大落差室外上/下(m)冷 房暖 房定格最大冷/暖液側/ガス側室 外20m以下50m以下25m以下室外中間低温冷房暖房冷暖中間定格室 内急・強・弱運 転 電 流(A)送風機出 力(kW)標準風量(m3/min)始動電流圧縮機出力(kW)最大長さ(m)チャージレス(m)電 気 特 性機 外 配 線室外H室内※3(A)※1※2内蔵補助H(kW)H室内全機種 高効率冷媒 R410A 採用afafafafafafafafafafafagagagahahag※5区分名※5区分名ahahagagahahahahahah室内側消 費電 力(kW)0.083×20.083×20.034×3①0.067②0.033×20.067×3①0.083②0.034×2①0.083②0.067×2①0.083×2②0.0340.034×40.067×4室内側消 費電 力(kW)0.0330.0330.0330.0330.0340.0340.0340.0340.0430.0430.0670.0830.0830.1110.5000.7000.7200.9100.034×2156 参照ページ 機能一覧→31 商品特長→67・73(大形) 形名価格→68・73(大形) 別売部品→72・73(大形) リモコン→5・93 外形図→181 工事→187▼す。☆工場出荷時の冷媒封入量は本カタログの189ページをご覧ください。  経済産業省告示213号 エアコンディショナーの性能の向上に関する製造事業者等の判断の基準等により定められた区分です。詳細は174ページを参照ください。※5

元のページ  ../index.html#157

このブックを見る