店舗・オフィス用カスタムエアコン2014年3月(増刷版)
153/204

仕様 ダクトスーパーパワーエコキューブP224・P280形スマートエコRP112~P140形P160形P40~P80形P224・P280形主5分5主5分5主5分5主5分5主5分5主5分5主5分5主5分52020202030主+分20主+分30主+分30主+分30主+分30主+分30主+分30●室内外渡り配線:室外~室内…3線、室内~室内…2線 ●リモコン渡り配線:主機~リモコン…2線、主機~従機…2線●ケースヒーター:P224・P280形…(0.026+0.026)kW ●ドレン配管:25Aオネジ(ツイン…×2 トリプル…×3 ダブルツイン…×4)●室内外渡り配線:室外~室内…3線、室内~室内…2線 ●リモコン渡り配線:主機~リモコン…2線、主機~従機…2線 ●ドレン配管:25Aオネジ(ツイン…×2 トリプル…×3)--------------------------------内0.260×2外0.600内0.260×2外0.600内0.160×3外0.600内①0.260内②0.160×2外0.600内①0.260内②0.160×2外0.600内①0.260×2内②0.160外0.600内0.160×4外0.600内0.160×4外0.60056/5756/5756/5756/5756/5756/5756/5756/57内(9.5/15.9)×2外(9.5/25.4内(9.5/15.9)×2外(12.7/25.4内(9.5/15.9)×3外(9.5/25.4内①(9.5/15.9内②(6.4/12.7)×2外9.5/25.4内①(9.5/15.9内②(9.5/15.9)×2外12.7/25.4内①(9.5/15.9)×2内②(6.4/12.7外12.7/25.4内(6.4/12.7)×4外(9.5/25.4内(9.5/15.9)×4外(12.7/25.414.014.014.014.014.014.014.014.038.038.038.038.038.038.038.038.060606060606060601.8×22.7×21.8×21.8×22.7×22.7×21.8×22.7×210010010010010010010010050/3050/3050/3050/3050/3050/3050/3050/30------------1.11.11.62.53.02.53.03.14.25.54.24.2959594959495949594959494内0.160外0.043内0.160外0.043内0.160外0.043内0.260外0.063内0.260外0.100内0.160×2外0.063内0.160×2外0.100内0.160×2外0.100×2内0.260×2外0.100×2内0.260×2外0.100×2内0.160×3外0.100×2内①0.260②0.160×2外0.100×20.1600.1800.1600.1800.2600.3500.3200.4100.3600.4500.160×20.180×20.260×20.350×20.260×20.350×20.320×20.410×20.360×20.450×20.260×30.350×3①0.320②0.160×2①0.410②0.180×2内15.0外40.0内15.0外40.0内22.0外45.0内26.7外56.7内35.0外70.0内15.0×2外56.7内22.0×2外70.0内22.0×2外103.0内26.7×2外133.3内35.0×2外150.0内22.0×3外133.3内①26.7②15.0×2外133.3------------3737404040374040404040①40②3747/4847/4848/5250/5452/5450/5452/5449/5156/575756/5756/57 6.4/12.7 6.4/12.7 9.5/15.9 9.5/15.9 9.5/15.9内(6.4/12.7)×2外(9.5/15.9内(9.5/15.9)×2外(9.5/15.9内(9.5/15.9)×2外(9.5/15.9内(9.5/15.9)×2外(9.5/25.4内(9.5/15.9)×2外(12.7/25.4内(9.5/15.9)×3外(9.5/25.4内①(9.5/15.9②(6.4/12.7)×2外9.5/25.4303030505050505070707070-5.55.514.014.014.014.014.022.022.022.022.03.5φ1.6φ2.05.55.55.55.55.58.014.08.08.030/3030/3030/3030/3030/3030/3030/3030/3030/3030/3030/3030/30151515203020303040504040------------------------1.611.621.611.622.432.483.533.584.684.773.533.584.684.775.005.096.656.738.078.166.656.736.656.730.6600.6800.6600.6801.031.121.471.561.711.801.471.561.711.801.942.032.422.473.023.072.422.472.422.472.472.492.472.493.263.353.623.714.604.693.623.714.604.696.776.867.687.7710.3410.517.687.777.687.778.478.534.894.927.467.6210.710.914.414.610.710.914.414.615.215.520.420.724.524.820.420.720.420.714.614.78.88.911.011.416.016.518.518.916.016.219.420.326.327.226.227.036.337.227.028.326.226.81.941.951.941.952.752.804.384.435.335.424.384.435.335.425.585.677.277.3810.1610.287.277.387.277.3810.210.35.905.938.458.6013.313.516.416.613.313.516.416.617.017.222.322.730.931.222.322.722.322.70.7900.8100.7900.8101.011.101.341.431.651.741.341.431.651.741.982.072.532.583.213.262.532.582.532.589595949594959495949594946.286.388.618.716.286.386.286.388.618.718.618.716.286.388.618.712.482.533.123.172.482.532.482.533.123.173.123.172.482.533.123.176.266.368.058.156.266.366.266.368.058.158.058.156.266.368.058.152.142.192.692.742.142.192.142.192.692.742.692.742.142.192.692.749.609.7211.2811.389.609.729.609.7211.2811.3811.2811.389.609.7211.2811.3819.820.026.526.919.820.019.820.026.526.926.526.919.820.026.526.919.419.624.625.319.419.619.419.624.625.324.625.319.419.624.625.342.042.849.750.542.844.142.042.650.551.950.151.141.942.451.453.2929492929494929493949493939493949493949393949493B224B280C224E224E280D280F224F280セット名 称運転音 (dB(A))消 費 電 力 (kW)力 率(%)冷媒配管(φmm) 最小電線 (φmm、mm2)ブレーカー(A)最大落差室外上/下(m)冷 房暖 房定格最大冷/暖液側/ガス側室 外20m以下50m以下25m以下室外中間低温冷房暖房冷暖中間定格室 内運 転 電 流(A)送風機出 力(kW)標準風量(m3/min)始動電流圧縮機出力(kW)補助H(kW)最大長さ(m)チャージレス(m)電 気 特 性機 外 配 線室外H室内H室内※3(A)※1※2A56JA56A80A112A140B112B140B160B224B280C224E224セット名 称運転音 (dB(A))消 費 電 力 (kW)力 率(%)冷媒配管(φmm) 最小電線 (φmm、mm2)ブレーカー(A)最大落差室外上/下(m)冷 房暖 房定格最大冷/暖液側/ガス側室 外20m以下50m以下25m以下室外中間低温冷房暖房冷暖中間定格室内運 転 電 流(A)送風機出 力(kW)始動電流圧縮機出力(kW)最大長さ(m)チャージレス(m)電 気 特 性機 外 配 線室外H室内※3(A)※1※2404040①40②37①40②40①40②373740内26.7×2外200.0内35.0×2外200.0内22.0×3外200.0内①26.7内②15.0×2外200.0内①35.0内②22.0×2外200.0内①26.7×2内②15.0外200.0内15.0×4外200.0内22.0×4外200.0※6標準風量(m3/min)※6別売補助H(kW)H室内*全機種 高効率冷媒 R410A 採用ahahahahahahahahafafafagagagagagahahahah※7区分名※7区分名室内側消 費電 力(kW)0.320×20.410×20.360×20.450×20.260×30.350×3①0.320②0.160×2①0.410②0.180×2①0.360②0.260×2①0.450②0.350×2①0.320×2②0.160①0.410×2②0.1800.160×40.180×40.260×40.350×4室内側消 費電 力(kW)152 参照ページ 機能一覧→31 商品特長→62 形名価格→63 別売部品→65 リモコン→5・93 外形図→180 工事→187▼ 機外静圧は出荷時137Pa(14mmAq)、結線切換えで69-137-196Pa(7-14-20mmAq)。180ページご参照。☆表中の数値は、製品改良などにより、変更する場合があります。☆工場出荷時の冷媒封入量は本カタログの189ページをご覧ください。  経済産業省告示213号 エアコンディショナーの性能の向上に関する製造事業者等の判断の基準等により定められた区分です。詳細は174ページを参照ください。※6※7

元のページ  ../index.html#153

このブックを見る