店舗・オフィス用カスタムエアコン2014年3月(増刷版)
155/204

仕様 ダクト・天井吊形スマートエコRP224・P280形P63・P80形P40~P56形P224・P280形P112~P160形スーパーパワーエコキューブ37.238.536.737.726.126.638.139.98.078.168.078.166.656.738.078.163.023.073.023.072.422.473.023.0710.3410.5110.3410.517.687.7710.3410.5124.524.824.524.820.420.724.524.895959495主+分30主+分30主+分30主+分30--------------------------------------------20202020202020203030303030303055主+分30主+分30主+分30主+分30主+分30●室内外渡り配線:室外~室内…3線、室内~室内…2線 ●リモコン渡り配線:主機~リモコン…2線、主機~従機…2線 ●ドレン配管:25Aオネジ(トリプル…×3 ダブルツイン…×4)●室内外渡り配線:室外~室内…3線、室内~室内…2線 ●リモコン渡り配線:主機~リモコン…2線、主機~従機…2線●ケースヒーター:P224・P280形…(0.026+0.026)kW ●ドレン配管:VP20 (ツイン…×2)----5.55.54.25.59595949510.1610.2810.1610.287.277.3810.1610.283.213.263.213.262.532.583.213.2630.931.230.931.222.322.730.931.2内①0.260②0.160×2外0.100×2①0.260×2内②0.160外0.100×2内0.160×4外0.100×2内0.160×4外0.100×2内①35.0②22.0×2外150.0①26.7×2内②15.0外150.0内15.0×4外133.3内22.0×4外150.0----①40②40①40②373740575756/57577070707022.022.022.022.014.014.08.014.030/3030/3030/3030/3050504050内①(9.5/15.9②(9.5/15.9)×2外12.7/25.4①(9.5/15.9)×2内②(6.4/12.7外12.7/25.4内(6.4/12.7)×4外(9.5/25.4内(9.5/15.9)×4外(12.7/25.4--------------------------------------------内0.094外0.043内0.094外0.043内0.094外0.043内0.094外0.043内0.094外0.043内0.094外0.043内0.094外0.043内0.094外0.043内0.094外0.060内0.094外0.060内0.094外0.060内0.094外0.060内0.139外0.100×2内0.139外0.100×2内0.139外0.100×2内0.16×2外0.600内0.16+0.19外0.600内0.094×2外0.060内0.094×2外0.060内0.094×2外0.100×2内0.094×2外0.100×2内0.094×2外0.100×2内14.0外40.0内14.0外40.0内14.0外40.0内14.0外40.0内15.0外40.0内15.0外40.0内15.0外40.0内15.0外40.0内19.5外50.0内19.5外50.0内23.5外50.0内23.5外50.0内31.0外101.0内31.0外103.0内34.0外103.0内58.0外200.0内70.0外200.0内14.0×2外50.0内14.0×2外50.0内15.0×2外101.0内23.5×2外103.0内23.5×2外103.036・34・2836・34・2836・34・2836・34・2837・35・2837・35・2837・35・2837・35・2837・35・2837・35・2841・36・2941・36・2944・38・3244・41・3546・42・3653・-・5055・-・5236・34・2836・34・2837・35・2841・36・2941・36・2945/4745/4745/4745/4745/4745/4746/4846/4846/4846/4846/4846/4848/5049/5149/5156/5756/5746/4846/4848/5049/5149/51 6.4/12.7 6.4/12.7 6.4/12.7 6.4/12.7 6.4/12.7 6.4/12.7 6.4/12.7 6.4/12.7 6.4/12.7 6.4/12.7 9.5/15.9 9.5/15.9 9.5/15.9 9.5/15.9 9.5/15.9 9.5/25.4 12.7/25.4内(6.4/12.7)×2外(9.5/15.9内(6.4/12.7)×2外(9.5/15.9内(6.4/12.7)×2外(9.5/15.9内(9.5/15.9)×2外(9.5/15.9内(9.5/15.9)×2外(9.5/15.9φ2.0φ1.6φ2.0φ1.65.5φ2.05.5φ2.05.5φ2.05.55.55.55.55.514.014.05.55.55.55.55.5-5.5-5.5-5.5-5.514.08.014.014.014.014.014.038.038.014.014.014.014.014.015151515151515152020302030303060603020303030303030305050505050505050757575100100505050505030/3030/3030/3030/3030/3030/3030/3030/3030/3030/3030/3030/3030/3030/3030/3050/3050/3030/3030/3030/3030/3030/301.11.11.11.11.11.11.11.11.11.11.41.41.72.53.11.8×22.7×21.41.41.72.53.1----1.051.051.281.281.481.481.901.901.521.522.192.192.804.295.246.606.768.869.022.192.192.804.295.240.3350.3350.3580.3580.4350.4350.4800.4800.4700.4700.5850.5850.8501.091.362.452.613.123.280.5850.5850.8501.091.360.9900.9901.181.181.251.251.441.441.651.652.172.172.883.784.645.996.158.228.382.172.172.883.784.640.3150.3150.3700.3700.3800.3800.4500.4500.4800.4800.6350.6350.8401.121.322.492.652.853.010.6350.6350.8401.121.321.901.902.022.022.122.122.372.372.502.503.193.194.386.136.3510.3410.5012.4612.623.193.194.386.136.355.833.377.114.118.224.7510.35.968.444.8812.06.958.7913.216.120.721.227.528.012.06.908.7913.216.15.503.186.563.786.944.018.004.629.175.2912.16.969.1411.714.218.819.325.526.012.17.009.1411.714.213.17.7413.17.7413.88.5813.98.6218.413.320.514.920.923.024.644.549.820.715.120.823.024.69090909090909292909091919294949293919192949490909090909090909090909091939492939090919394E280D280F224F280----A40JA40A45JA45A50JA50A56JA56A63JA63A80JA80A112A140A160A224A280B80JB80B112B140B160セット名 称運転音 (dB(A))消 費 電 力 (kW)力 率(%)冷媒配管(φmm)最小電線(φmm、mm2)ブレーカー (A)最大落差室外上/下(m)冷 房暖 房定格最大冷/暖液側/ガス側室 外20m以下50m以下25m以下室外中間低温冷房暖房冷暖中間定格室 内急・強・弱運 転 電 流(A)送風機出 力(kW)標準風量(m3/min)始動電流圧縮機出力(kW)補助H(kW)最大長さ(m)チャージレス(m)電 気 特 性機 外 配 線室外H室内H室内※3(A)※1※2セット名 称運転音 (dB(A))消 費 電 力 (kW)力 率(%)冷媒配管(φmm)最小電線(φmm、mm2)ブレーカー (A)最大落差室外上/下(m)冷 房暖 房定格最大冷/暖液側/ガス側室 外20m以下50m以下25m以下室外中間低温冷房暖房冷暖中間定格室内運 転 電 流(A)送風機出 力(kW)標準風量(m3/min)始動電流圧縮機出力(kW)最大長さ(m)チャージレス(m)電 気 特 性機 外 配 線室外H室内※3※6(A)※1※2別売補助H(kW)H室内*全機種 高効率冷媒 R410A 採用afafafafafafafafafafafafagagagahahafafagagag※7区分名※7区分名ahahahah室内側消 費電 力(kW)①0.360②0.260×2①0.450②0.350×2①0.320×2②0.160①0.410×2②0.1800.160×40.180×40.260×40.350×4室内側消 費電 力(kW)0.0330.0330.0330.0330.0340.0340.0340.0340.0430.0430.0670.0670.0830.0830.1110.5000.7000.7200.9100.033×20.033×20.034×20.067×20.067×2154 機外静圧は出荷時137Pa(14mmAq)、結線切換えで69-137-196Pa(7-14-20mmAq)。180ページご参照。☆表中の数値は、製品改良などにより、変更する場合があります。☆工場出荷時の冷媒封入量は本カタログの189ページをご覧ください。 経済産業省告示213号 エアコンディショナーの性能の向上に関する製造事業者等の判断の基準等により定められた区分です。詳細は174ページを参照ください。※7 参照ページ(ダクト/天吊形) 機能一覧→31 商品特長→62/67・73(大形) 形名価格→63/68・73(大形) 別売部品→65/72・73(大形) リモコン→5・93 外形図→180/181 工事→187▼※6

元のページ  ../index.html#155

このブックを見る