店舗・オフィス用カスタムエアコン「スーパーパワーエコ ゴールド」2014年12月版
116/138

115天井埋込形ダクトタイプ天井吊形大容量380×850×660×21,340×900×320380×850×660×21,550×1,010×370380×850×660×21,550×1,010×370380×850×660×21,800×990×750380×1,200×660×21,800×990×750380×850×660×31,800×990×750380×850×660380×850×660×21,800×990×750380×1,200×660380×850×660×21,800×990×750380×850×660×2380×850×6601,800×990×750380×850×660×41,800×990×750380×850×660×41,800×990×750電源V能 力(kW)〈 〉内は能力範囲COP(エネルギー消費効率)冷 房定 格中間冷 房暖 房定格冷暖平均中間中間定格定 格中間低温暖 房定 格冷房時顕熱比*APF外形寸法(mm)高さ×幅×奥行10.0〈2.6~11.2〉12.5〈3.1~14.0〉14.0〈3.1~16.0〉20.0〈6.0~22.4〉25.0〈6.0~28.0〉20.0〈6.0~22.4〉20.0〈6.0~22.4〉25.0〈6.0~28.0〉25.0〈6.0~28.0〉20.0〈6.0~22.4〉25.0〈6.0~28.0〉22.4〈6.0~25.0〉28.0〈6.0~31.5〉28.0〈6.0~31.5〉22.4〈6.0~25.0〉28.0〈6.0~31.5〉11.2〈2.4~14.0〉14.0〈2.6~18.0〉16.0〈2.6~20.0〉22.4〈6.0~25.0〉28.0〈6.0~31.5〉22.4〈6.0~25.0〉ADSB 112 56ADSB 140 56ADSB 160 56ADSB 224 55ADSB 280 55ADSC 224 55ADSE 224 55ADSE 280 55ADSD 280 55ADSF 224 55ADSF 280 55内外内外内外内外内外内外内① ②外内① ②外内① ②外内外内外AID-AP565H×2ROA-AP1126HSAID-AP715H×2ROA-AP1406HSAID-AP805H×2ROA-AP1606HSAID-AP1125H×2ROB-AP2245HSAID-AP1405H×2ROB-AP2805HSAID-AP805H×3ROB-AP2245HS AID-AP1125H AID-AP565H×2ROB-AP2245HS AID-AP1405H AID-AP715H×2ROB-AP2805HS AID-AP1125H×2 AID-AP565HROB-AP2805HSAID-AP565H×4ROB-AP2245HSAID-AP715H×4ROB-AP2805HS内外内外内外内外内外内外①②外①②外①②外内外内外天埋ダクト 同時ツイン天埋ダクト 同時トリプルダブルツイン天井吊形 シングル大容量暖冷※14.65.76.39.111.69.19.111.611.69.111.64.44.24.14.24.14.24.24.14.14.24.1agagagahahahahahahahah5.16.37.210.312.810.310.312.812.810.312.8*APF…通年エネルギー消費効率※5区分名セット名称三200三200三200三200三200三200三200三200三200三200三20012.214.715.522.027.222.022.027.227.222.027.20.850.900.900.770.820.900.770.820.770.850.903.333.233.042.982.832.773.183.132.902.873.183.133.183.132.902.872.902.873.183.132.902.874.514.184.073.854.294.063.673.603.723.663.673.603.673.603.723.663.723.663.673.603.723.663.603.503.453.383.283.213.583.523.483.443.583.523.583.523.483.443.483.443.583.523.483.444.434.114.504.234.344.094.814.704.764.674.814.704.814.704.764.674.764.674.814.704.764.673.473.373.253.183.062.993.383.333.193.163.383.333.383.333.193.163.193.163.383.333.193.16119120121122123124125126127128129001…呼出番号は本カタログのみ有効です(A・M)はリモコン名を示します右ページ上ご参照天井埋込形 ダクトタイプ・天井吊形・大容量天井埋込形 ダクトタイプR410A※1冷房・暖房能力はダクトタイプ/JISB8615-2、天井吊形/JISB8615-1により、冷媒配管長7.5m(P40~P63形は5m)、落差0m時の値。※2電気特性は定格能力時の値。※3運転音はJIS規格に準拠し、無響室で測定した値。室内ユニットは本体下方1.5m(天井吊形は本体下方1m、前方1m)、室外機は本体前方1m、高さ1.5mでの測定値。実際に据付けた状態で測定すると周囲の騒音や反響を受け、表示値より大きくなるのが普通です。複数台システムの運転音は1台当たりの値。※4配管部分のカバーが71mmプラスされます。☆表中の数値は、製品改良などにより、変更する場合があります。☆工場出荷時の冷媒封入量は本カタログの127ページをご覧ください。※5経済産業省告示213号 エアコンディショナーの性能の向上に関する製造事業者等の判断の基準等により定められた区分です。詳細は124ページをご参照ください。※7機外静圧は出荷時137Pa(14mmAq)、結線切換えで69-137-196Pa(7-14-20mmAq)。56ページご参照。ACSA 040 76J  2ACSA 040 76  2ACSA 045 76J  2ACSA 045 76  2ACSA 050 76J  2ACSA 050 76  2ACSA 056 76J  2ACSA 056 76  2ACSA 063 76J  2ACSA 063 76  2ACSA 080 76J  2ACSA 080 76  2ACSA 112 76  2ACSA 140 76  2ACSA 160 76  2ACSA 224 25ACSA 280 25内外内外内外内外内外内外内外内外内外内外内外内外内外内外内外内外内外AIC-AP407H-1ROA-AP406HSJAIC-AP407H-1ROA-AP406HSAIC-AP457H-1ROA-AP456HSJAIC-AP457H-1ROA-AP456HSAIC-AP507H-1ROA-AP506HSJAIC-AP507H-1ROA-AP506HSAIC-AP567H-1ROA-AP566HSJAIC-AP567H-1ROA-AP566HSAIC-AP637H-1ROA-AP636HSJAIC-AP637H-1ROA-AP636HSAIC-AP807H-1ROA-AP806HSJAIC-AP807H-1ROA-AP806HSAIC-AP1127H-1ROA-AP1126HSAIC-AP1407H-1ROA-AP1406HSAIC-AP1607H-1ROA-AP1606HSAIC-AP2242HROB-AP2245HSAIC-AP2802HROB-AP2805HS1.71.71.81.82.12.12.32.32.62.63.43.44.65.76.39.111.65.25.25.15.15.25.25.05.05.45.45.35.35.45.25.04.04.0afafafafafafafafafafafafagagagahah1.81.82.12.12.32.32.62.62.92.93.63.65.16.37.210.312.84.94.95.15.15.95.96.26.27.47.48.58.511.615.015.422.027.20.820.820.770.770.730.730.700.700.800.800.740.740.740.690.690.750.733.433.433.133.133.043.042.632.633.683.683.243.243.573.032.803.032.962.822.775.075.075.035.034.834.834.794.795.535.535.815.815.415.235.253.713.493.723.544.044.043.813.814.004.003.893.893.823.823.693.693.893.913.713.743.643.413.345.715.715.685.686.056.055.785.786.046.045.675.676.075.895.674.143.894.494.253.743.743.473.473.523.523.263.263.753.753.473.473.733.473.263.393.303.123.06内外内外内外内外内外内外内外内外内外内外内外内外内外内外内外内外内外132134133130131135138140139136137141144146145142143電源V能 力(kW)〈 〉内は能力範囲COP(エネルギー消費効率)冷 房定 格中間冷 房暖 房定格冷暖平均中間中間定格定 格中間低温暖 房定 格冷房時顕熱比*APF外形寸法(mm)高さ×幅×奥行暖冷※1※5区分名セット名称001…呼出番号は本カタログのみ有効です(A・M・X)はリモコン名を示します右ページ上ご参照天井吊形235×950×690550×780 ×290235 ×950×690550×780 ×290235×950×690550×780 ×290235×950×690550×780 ×290235×950×690550×780 ×290235×950×690550×780 ×290235×950×690550×780 ×290235×950×690550×780 ×290235×1,270×690890×900×320235×1,270×690890×900×320235×1,270×690890×900×320235×1,270×690890×900×320235×1,586×6901,340×900×320235 ×1,586×6901,550×1,010×370235×1,586×6901,550×1,010×370320×1,800×8001,800×990×750320×2,100×8001,800×990×750※4※4※4※4※4※4※4※4 (A・M・X) (A・M・X) (A・M・X) (A・M・X) (A・M・X) (A・M・X) (A・M・X) (A・M・X) (A・M・X) (A・M・X) (A・M・X) (A・M・X) (A・M・X) (A・M・X) (A・M・X)(A・M)(A・M)(A・M)(A・M) (A・M)(A・M)(A・M)(A・M)(A・M) (A・M) (A・M) (A・M) (A・M)単200単200単200単200単200単200三200三200三200三200三200三200三200三200三200三200三2003.6〈1.0~4.0〉3.6〈1.0~4.0〉4.0〈1.0~4.5〉4.0〈1.0~4.5〉4.5〈1.2~5.0〉4.5〈1.2~5.0〉5.0〈1.2~5.6〉5.0〈1.2~5.6〉5.6〈1.8~6.3〉5.6〈1.8~6.3〉7.1〈1.9~8.0〉7.1〈1.9~8.0〉10.0〈2.6~11.2〉12.5〈3.1~14.0〉14.0〈3.1~16.0〉20.0〈6.0~22.4〉25.0〈6.0~28.0〉4.0〈0.8~6.4〉4.0〈0.8~6.4〉4.5〈0.8~6.7〉4.5〈0.8~6.7〉5.0〈0.9~7.2〉5.0〈0.9~7.2〉5.6〈0.9~7.4〉5.6〈0.9~7.4〉6.3〈1.3~9.1〉6.3〈1.3~9.1〉8.0〈1.3~10.6〉8.0〈1.3~10.6〉11.2〈2.4~15.6〉14.0〈2.6~18.5〉16.0〈2.6~20.0〉22.4〈6.0~25.0〉28.0〈6.0~31.5〉スーパーパワーエコゴールド・キューブ50605060506050605060506050605060506050605060Hz50605060506050605060506050605060506050605060506050605060506050605060Hz仕様 ダクト・天井吊形

元のページ  ../index.html#116

このブックを見る