店舗・オフィス用カスタムエアコン 2016年4月新価格版(確定版)
164/228

163天井カセット形4方向吹出しタイプ天井カセット形2方向吹出しタイプ(M・X)(M・X)(M・X)(M・X)(M・X)(M・X)(M・X)(M・X)(M・X)(M・X)(M・X)(M・X)(M・X)(M・X)(M・X)(M・X)(M・X)(M・X)(M・X)(M・X)(M・X)(M・X)(M・X)(M・X)(M・X)(M・X)(M・X)(M・X)(M・X)(M・X)電源V能力(kW)〈 〉内は能力範囲冷 房定 格定 格暖 房*APF2015定 格冷房時顕熱比消 費 電 力(kW)力 率(%)冷房暖 房定格最大冷房暖房冷暖定格運 転 電 流(A)始動電流圧縮機出力電 気 特 性※1(A)(kW)*APF…通年エネルギー消費効率※1※2セット名称909090909191919190909292939495929293949594959594949590909090919191919090919193949591919394959495959494951.741.741.831.831.991.992.252.252.772.773.213.214.225.986.093.213.214.225.986.098.209.356.098.208.209.354.782.765.613.246.043.497.254.197.944.5910.15.847.1111.013.910.15.847.1111.013.917.827.313.917.817.827.34.782.765.723.305.883.397.094.098.504.9110.56.067.3910.112.010.56.067.3910.112.016.322.912.016.316.322.913.07.6013.07.6013.78.5013.78.5018.213.120.514.921.223.424.520.514.921.223.424.527.837.824.527.427.837.80.8600.8601.011.011.101.101.321.321.431.431.861.862.293.584.561.861.862.293.584.565.808.994.565.805.808.990.8600.8601.031.031.071.071.291.291.531.531.911.912.383.293.951.911.912.383.293.955.297.553.955.295.297.55101…呼出番号は本カタログのみ有効です天井カセット形 4方向吹出し・2方向吹出しR410A(M・X)はリモコン名を示します右ページ上ご参照※3AUSA 040 76JAUSA 040 76AUSA 045 76JAUSA 045 76AUSA 050 76JAUSA 050 76AUSA 056 76JAUSA 056 76AUSA 063 76JAUSA 063 76AUSA 080 76JAUSA 080 76AUSA 112 76AUSA 140 76AUSA 160 76AUSB 080 76JAUSB 080 76AUSB 112 76AUSB 140 76AUSB 160 76AUSB 224 76AUSB 280 76AUSC 160 76AUSC 224 76AUSF 224 76AUSF 280 76天カセ4方向 シングル天カセ4方向 同時ツイン同時トリプル同時ダブルツイン101102103104105106107108109110111112113114115116117118119120121122123125129130AIU-AP407HROA-AP406HSJAIU-AP407HROA-AP406HSAIU-AP457HROA-AP456HSJAIU-AP457HROA-AP456HSAIU-AP507HROA-AP506HSJAIU-AP507HROA-AP506HSAIU-AP567HROA-AP566HSJAIU-AP567HROA-AP566HSAIU-AP637HROA-AP636HSJAIU-AP637HROA-AP636HSAIU-AP807HROA-AP806HSJAIU-AP807HROA-AP806HSAIU-AP1127HROA-AP1126HSAIU-AP1407HROA-AP1406HSAIU-AP1607HROA-AP1606HSAIU-AP407H×2ROA-AP806HSJAIU-AP407H×2ROA-AP806HSAIU-AP567H×2ROA-AP1126HSAIU-AP717H×2ROA-AP1406HSAIU-AP807H×2ROA-AP1606HSAIU-AP1127H×2ROA-AP2246HSAIU-AP1407H×2ROA-AP2806HSAIU-AP507H×3ROA-AP1606HSAIU-AP807H×3ROA-AP2246HSAIU-AP567H×4ROA-AP2246HSAIU-AP717H×4ROA-AP2806HS単200三200単200三200単200三200単200三200単200三200単200三200三200三200三200単200三200三200三200三200三200三200三200三200三200三200内外内外内外内外内外内外内外内外内外内外内外内外内外内外内外内外内外内外内外内外内外内外内外内外内外内外3.6〈1.0~4.0〉3.6〈1.0~4.0〉4.0〈1.0~4.5〉4.0〈1.0~4.5〉4.5〈1.2~5.0〉4.5〈1.2~5.0〉5.0〈1.2~5.6〉5.0〈1.2~5.6〉5.6〈1.8~6.3〉5.6〈1.8~6.3〉7.1〈1.9~8.0〉7.1〈1.9~8.0〉10.0〈2.6~11.2〉12.5〈3.1~14.0〉14.0〈3.1~16.0〉7.1〈1.9~8.0〉7.1〈1.9~8.0〉10.0〈2.6~11.2〉12.5〈3.1~14.0〉14.0〈3.1~16.0〉20.0〈4.6~22.4〉25.0〈4.6~28.0〉14.0〈3.1~16.0〉20.0〈4.6~22.4〉20.0〈4.6~22.4〉25.0〈4.6~28.0〉4.0〈0.8~6.4〉4.0〈0.8~6.4〉4.5〈0.8~6.7〉4.5〈0.8~6.7〉5.0〈0.9~7.6〉5.0〈0.9~7.6〉5.6〈0.9~8.1〉5.6〈0.9~8.1〉6.3〈1.3~10.3〉6.3〈1.3~10.3〉8.0〈1.3~11.3〉8.0〈1.3~11.3〉11.2〈2.4~15.6〉14.0〈2.6~20.0〉16.0〈2.6~20.7〉8.0〈1.3~11.3〉8.0〈1.3~11.3〉11.2〈2.4~15.6〉14.0〈2.6~20.0〉16.0〈2.6~20.7〉22.4〈4.6~28.0〉28.0〈4.6~35.0〉16.0〈2.6~20.7〉22.4〈4.6~28.0〉22.4〈4.6~28.0〉28.0〈4.6~35.0〉5.05.05.25.25.85.86.36.37.87.88.88.812.715.515.78.88.812.715.515.722.124.015.724.022.122.10.910.910.860.860.800.800.840.840.790.790.880.880.860.770.740.910.910.840.880.880.840.770.800.820.880.786.56.56.46.46.86.86.76.76.46.46.56.56.46.15.96.56.56.46.15.96.05.55.96.06.05.53.15.65.63.15.65.65.62.51.71.41.43.12.51.71.41.41.11.11.11.11.11.11.11.11.11.1--------------------------※1冷房・暖房能力はJISB8615-1により、冷媒配管長7.5m(P40~P63形は5m)、落差0m時の値。※2電気特性は定格能力時の値。※3APF2015、運転音(音響パワーレベル)はJISB8616:2015に準拠した値です。複数台システムの運転音は1台当たりの値。※4配管分のカバーが69mmプラスされます。☆表中の数値は、製品改良などにより、変更する場合があります。☆工場出荷時の冷媒封入量は本カタログの213ページをご覧ください。低温★低温★★JIS B 8616:2015の最大低温を表します。ゴールド暖冷天井カセット形 4方向吹出しタイプ電源V能力(kW)〈 〉内は能力範囲冷 房定 格定 格暖 房*APF2015定 格冷房時顕熱比消 費 電 力(kW)力 率(%)冷房暖 房定格最大冷房暖房冷暖定格運 転 電 流(A)始動電流圧縮機出力電 気 特 性※1(A)(kW)※1※2セット名称131…呼出番号は本カタログのみ有効ですAWSA 040 56JAWSA 040 56AWSA 045 56JAWSA 045 56内外内外内外内外AIU-AP405WHROA-AP406HSJAIU-AP405WHROA-AP406HSAIU-AP455WHROA-AP456HSJAIU-AP455WHROA-AP456HS天カセ2方向吹出し シングル131132133134単200三200単200三2003.6〈1.0~4.0〉3.6〈1.0~4.0〉4.0〈1.0~4.5〉4.0〈1.0~4.5〉4.0〈0.8~6.4〉4.0〈0.8~6.4〉4.5〈0.8~6.7〉4.5〈0.8~6.7〉4.94.95.15.10.720.720.690.695.65.65.45.42.032.032.162.1690909292909092925.523.196.633.835.373.106.583.8013.0 7.6013.0 7.600.9940.9941.22 1.22 0.9660.9661.21 1.21 ----1.11.11.11.1※3低温★低温★★JIS B 8616:2015の最大低温を表します。(M・X)はリモコン名を示します右ページ上ご参照暖冷天井カセット形 2方向吹出しタイプ仕様 4方向・2方向ゴールド

元のページ  ../index.html#164

このブックを見る