東芝換気・送風機 設計・工事専門家用 2011年
311/716

■天井埋込形(基本形)形  名定 格ノッチ周波数(Hz)全 熱 交 換 換 気普 通 換 気質 量(kg)消費電力(W)電  流(A)風  量(m3/h)機外静圧(Pa)熱交換率(%)エンタルピー交換率(%)騒  音(dB)消費電力(W)電  流(A)風  量(m3/h)機外静圧(Pa)騒  音(dB)冷房時暖房時VN-150SS2VN-M150SS2単相100V特強50600.611509075637026600.61150902625(26)60750.7615012075637027750.7615012027強50550.561504075637024550.56150402460650.661506075637025650.661506025弱50500.511102578677420500.51110252060500.511053079687520500.511053020VN-150ST2VN-M150ST2単相200V特強50600.311509075637026600.31150902625(26)60750.3815012075637027750.3815012027強50550.281504075637024550.28150402460650.331506075637025650.331506025弱50500.251102578677420500.25110252060500.261053079687520500.261053020VN-250SS2VN-M250SS2単相100V特強501101.1225085756370281101.12250852829(30)601251.26250120756370281251.2625012028強50950.962505575637026950.962505526601101.1125065756370261101.112506526弱50780.791652578677421780.79165252160780.791502478687521780.791502421VN-250ST2VN-M250ST2単相200V特強501100.5625085756370281100.56250852829(30)601300.66250120756370281300.6625012028強501050.5425055756370261050.542505526601200.6225065756370261200.622506526弱50780.411652578677421780.41165252160780.461502478687521780.461502421VN-350SS2VN-M350SS2単相100V特強501301.31350125756669311301.313501253137(38)601701.71350190756669321701.7135019032強501101.1135065756669281101.113506528601401.4135060756669271401.413506027弱50800.812453178717421800.81245312160850.862352879727521850.862352821VN-350ST2VN-M350ST2単相200V特強501300.68350125756669311300.673501253137(38)601700.87350190756669321700.8735019032強501180.6235065756669281180.623506528601480.7935060756669271480.803506027弱501150.6124531787174211150.592453121601250.6823528797275211250.672352821VN-500SS2VN-M500SS2単相100V特強501751.76500130756267331701.715001303443(44)602352.36500200756267342302.3150020035強501551.565007075626729.51501.515007032602002.015007075626729.52002.015007032弱501301.3134535786873241301.313453524601451.4631028796974241451.463102824VN-500ST2VN-M500ST2単相200V特強501750.90500130756267331700.875001303443(44)602251.14500200756267342301.1750020035強501600.825007075626729.51600.825007032602001.105007075626729.52001.075007032弱501550.8034535786873241550.793453524601700.9031028796974241700.903102824VN-650SS2VN-M650SS2単相100V特強502502.606509075626834.52502.606509034.564(65)603303.3165018575626835.53303.3165018536.5強502202.306505075626832.52202.306505033603003.106507075626832.53003.106507033弱501801.9050030786471271801.905003027602002.1046035796572272002.104603527VN-650ST2VN-M650ST2単相200V特強502501.436509075626834.52501.396509034.564(65)603501.7765018575626835.53501.8065018536.5強502401.226505075626832.52401.206505033603001.536507075626832.53001.536507033弱502251.1450030786471272251.155003027602701.3746035796572272701.404603527VN-800SS2VN-M800SS2単相100V特強504004.70800140756571364004.708001403671(72)605005.20800250756571374805.2080025038強503604.00800100756571343604.0080010034604604.90800120756571344204.9080012035弱503003.3065066766874312703.306506631603503.8064075766975313003.806407531VN-800ST2VN-M800ST2単相200V特強503501.90800140756571363501.758001403671(72)604602.32800230756571374402.2080023038強503301.67800100756571343301.6780010034604302.23800140756571344202.1580014035弱503201.6067575766874313201.626757531603801.9762085766975313801.966208531VN-1KSS2-AVN-M1KSS2-A単相100V特強505405.501000160756571375205.5010001603983(84)強4905.501000110756571354605.50100011037弱3803.9081072776874323303.908107234VN-1KSS2-BVN-M1KSS2-B特強606306.401000200756571376206.40100020039強5605.701000120756571355605.70100012037弱4004.1076065786975313804.107606533VN-1KST2-AVN-M1KST2-A単相200V特強504602.321000160756571374602.3210001603983(84)強4402.221000100756571354402.22100010037弱4102.0781568786874324102.068156834VN-1KST2-BVN-M1KST2-B特強605552.851000200756571375552.83100020039強4802.551000110756571354802.52100011037弱4202.2380070786874324202.228007034※消費電力、電流、交換率は表記風量時の値です。※騒音値は、本体中央1.5m下方によるものです。※熱交換率は、冷房時、暖房時の平均値を示します。※形名は、上段は標準タイプ、下段は、マイコンタイプです。※( )内は、マイコンタイプの値です。業務用・全熱交換ユニット本カタログ掲載商品の価格には、配送費、設置調整費、工事費、使用済み商品の引き取り費等は含まれておりません。特性一覧表業務用・全熱交換ユニット310

元のページ  ../index.html#311

このブックを見る