東芝換気・送風機 設計・工事専門家用 2014年
286/668

業務用・全熱交換ユニット■天井埋込形(基本形マイコンタイプ) 形  名定 格ノッチ周波数(Hz)全 熱 交 換 換 気普 通 換 気質 量(kg)消費電力(W)電  流(A)風  量(m3/h)機外静圧(Pa)熱交換率(%)エンタルピー交換率(%)騒  音(dB)消費電力(W)電  流(A)風  量(m3/h)機外静圧(Pa)騒  音(dB)冷房時暖房時VN-M150HS単相100V強50680.691508081.569.574.525.5全熱交換換気と同値3660780.8115010481.569.574.527.5弱50350.351103483.071.076.018.060380.38955383.572.077.019.5VN-M150HT単相200V強50620.321506081.569.574.527.0全熱交換換気と同値3660690.351507081.569.574.527.5弱50430.221154083.071.076.021.060460.241104483.571.576.521.0VN-M250HS単相100V強501061.162508178.065.070.027.0全熱交換換気と同値36601171.2725010678.065.070.030.0弱50470.511554081.569.074.021.060500.531306082.570.575.522.5VN-M250HT単相200V強501180.622508678.065.070.031.0全熱交換換気と同値36601300.662509678.065.070.032.0弱50520.281502981.569.574.519.560540.281303982.570.575.521.0VN-M350HS単相100V特強501671.8335012774.560.565.032.5全熱交換換気と同値38601982.3035017074.560.565.034.5強501501.5835010274.560.565.031.5601841.9835012174.560.565.032.5弱50860.892102879.567.071.520.560880.921802780.568.073.018.5VN-M350HT単相200V特強501510.7635012874.560.565.032.5全熱交換換気と同値38601890.9635017574.560.565.034.0強501380.6935010074.560.565.031.5601740.8735011174.560.565.032.5弱50870.442256079.066.071.025.060970.492203779.066.571.022.5VN-M500HS単相100V特強502102.5350014676.564.572.034.0全熱交換換気と同値53602643.1050020676.564.572.035.5強501842.1650012076.564.572.032.0602292.5450015376.564.572.034.5弱501251.403908478.066.573.527.5601411.5334010478.567.574.528.5VN-M500HT単相200V特強502091.0750014076.564.572.034.5全熱交換換気と同値53602601.3050018376.564.572.036.5強501920.9850011076.564.572.033.5602321.1750012976.564.572.034.0弱501070.553304678.568.074.524.0601160.593153578.568.075.022.5VN-M650HS単相100V特強502783.0365010375.061.569.534.5全熱交換換気と同値53603233.5965016875.061.569.535.5強502462.596507175.061.569.533.0602913.0565010375.061.569.534.5弱501781.925206076.564.071.528.5601962.1445510977.065.572.529.0VN-M650HT単相200V特強502771.476509175.061.569.536.5全熱交換換気と同値53603271.6565013075.061.569.537.5強502551.346506075.061.569.535.0603001.536506575.061.569.535.5弱501720.904803976.565.072.030.0601890.974552977.065.572.529.5VN-M800HS単相100V特強504094.7880015476.564.071.038.0全熱交換換気と同値70605236.0980020376.564.071.040.0強503624.0680011876.564.071.036.5604564.9880014076.564.071.037.5弱502903.2070010477.565.571.534.0603503.7566012678.066.072.035.5VN-M800HT単相200V特強503992.0780013576.564.071.037.0全熱交換換気と同値70604812.4380015376.564.071.037.5強503821.9880010876.564.071.036.0604572.3280010876.564.071.035.5弱503041.586907877.565.572.532.0603411.736457978.566.573.031.5VN-M1000HS単相100V特強505906.55100012573.560.568.540.0全熱交換換気と同値70606807.99100019573.560.568.542.0強505425.80100010473.560.568.539.5606376.99100013873.560.568.540.5弱503473.767557277.064.571.534.0603854.1669010477.565.572.535.0VN-M1000HT単相200V特強505582.94100013073.560.568.539.0全熱交換換気と同値70606583.35100017873.560.568.540.0強505342.77100010773.560.568.538.5606353.33100012073.560.568.539.0弱503731.937707376.564.571.533.5604232.137505677.064.571.533.0※消費電力、電流、交換率は表記風量時の値です。※騒音値は、本体中央1.5m下方によるものです。※熱交換率は、冷房時、暖房時の平均値を示します。業務用・全熱交換ユニット特性一覧表285

元のページ  ../index.html#286

このブックを見る