換気・送風機 設計・工事専門家用 2020年4月
170/628

パイプ用ファン 有効換気量・比消費電力 一覧表形  名接続ダクトφ(mm)速調消費電力(W)有効換気量(m3/h)比消費電力(W/(m3/h))長形パイプフード長形パイプフード(FD付)長形パイプフード長形パイプフード(FD付)DV-142CLUY(SUS)DV-142CLDUY(SUS)DV-142CLUY(SUS)DV-142CLDUY(SUS)DV-141CLUY(アルミ製)DV-141CLDUY(アルミ製)DV-141CLUY(アルミ製)DV-141CLDUY(アルミ製)50Hz60Hz50Hz60Hz50Hz60Hz50Hz60Hz50Hz60HzVFP-8C31001.82.256.956.352.651.80.040.040.040.05VFP-8CS31001.82.256.956.352.651.80.040.040.040.05VFP-8CSS31001.82.256.956.352.651.80.040.040.040.05VFP-8CSSP31002.73.167.164.261.458.80.050.050.050.06VFP-8G41001.72.257.358.352.9540.030.040.040.05VFP-8GK4△1003.13.646.247.844.746.50.070.080.070.08VFP-8GKS4△1003.13.646.247.844.746.50.070.080.070.08VFP-8PXHSD 100強4.14.354.5535048.90.080.090.090.09弱3.2337.631.334.128.70.090.10.10.11VFP-8PXKSD 100強4.14.354.5535048.90.080.090.090.09弱3.2337.631.334.128.70.090.10.10.11VFP-8PXS 1003.73.956.653.851.849.10.070.080.080.08VFP-8R41001.72.259.462.354.557.60.030.040.040.04VFP-8T41001.72.258.860.653.855.50.030.040.040.04VFP-8TP41003.64.38389.875.981.30.050.050.050.06VFP-8TPY41003.64.38389.875.981.30.050.050.050.06VFP-8TY41001.72.258.860.653.855.50.030.040.040.04VFP-8V41002.73.145.949.444.647.90.060.070.070.07VFP-8VB1002.73.145.949.444.647.90.060.070.070.07VFP-8VY41003.23.852.756.751.154.70.070.070.070.07VFP-8W41002.73.240.545.639.1440.070.080.070.08VFP-8WS31001.82.251.650.947.746.90.040.050.040.05VFP-8WS41002.73.240.545.639.1440.070.080.070.08VFP-8WSS31001.82.251.650.947.746.90.040.050.040.05VFP-8WSSL31001.41.527.629.325.927.20.060.060.060.06VFP-8WUF31001.51.822.323.922.323.80.070.080.070.08VFP-8WUF3(T)1001.51.822.323.922.323.80.070.080.070.08VFP-8WUFF31001.51.819.620.319.520.30.080.090.080.09VFP-8WUFF3(T)1001.51.819.620.319.520.30.080.090.080.09VFP-8X21003.63.946.247.844.746.50.080.090.090.09VFP-8X2B1003.63.946.247.844.746.50.080.090.090.09VFP-8XHS2△10044.346.247.844.746.50.090.090.090.1VFP-8XHSD2100強44.346.247.844.746.50.090.090.090.1弱3.1331.431.33030.10.10.10.110.1VFP-8XK2△10044.346.247.844.746.50.090.090.090.1VFP-8XKS2△10044.346.247.844.746.50.090.090.090.1VFP-8XKSD2100強44.346.247.844.746.50.090.090.090.1弱3.1331.431.33030.10.10.10.110.1VFP-8XS21003.63.946.247.844.746.50.080.090.090.09VFP-8Z41002.73.145.949.444.647.90.060.070.070.07VFP-8ZB1002.73.145.949.444.647.90.060.070.070.07VFP-8ZP41002.73.145.949.444.647.90.060.070.070.07VFP-8ZS41002.73.145.949.444.647.90.060.070.070.07VFP-8ZSY41003.23.852.756.55154.60.070.070.070.07VFP-8ZY41003.23.852.756.751.154.70.070.070.070.07VFP-C8C1001.82.256.956.352.651.80.040.040.040.05VFP-C8CS1001.82.256.956.352.651.80.040.040.040.05VFP-C8CSS1001.82.256.956.352.651.80.040.040.040.05VFP-C8CSSP10033.366.468.360.462.20.050.050.050.06VFP-C8F10022.34746.943.843.40.050.050.050.06VFP-C8FS10022.34746.943.843.40.050.050.050.06VFP-C8FSS10022.34746.943.843.40.050.050.050.06VFP-C8FSSP1002.83.152.849.94945.90.060.070.060.07VFP-C8WS1001.82.251.650.947.746.90.040.050.040.05VFP-C8WS(T)1001.82.251.650.947.746.90.040.050.040.05VFP-C8WSS1001.82.251.650.947.746.90.040.050.040.05VFP-C8WSS(T)1001.82.251.650.947.746.90.040.050.040.05VFP-C8WSSL1001.41.525.326.324.1250.060.060.060.06VFP-C8WSSP10033.263.764.958.659.50.050.050.060.06VFP-C8WUF1001.51.820.521.520.521.50.080.090.080.09VFP-C8WUF(T)1001.51.820.521.520.521.50.080.090.080.09VFP-C8WUFF1001.51.818.219.218.219.20.090.10.090.1VFP-C8WUFF(T)1001.51.818.219.218.219.20.090.10.090.1VFP-C8WUFV 1001.51.812.914.112.914.10.120.130.120.13※△は24時間換気システムとしてご使用の場合は、本体のスイッチを「連続」にしてお使いください。その場合、センサー運転はできません。※消費電力は静圧0Pa時の値です ※比消費電力は小数点以下第3位を繰り上げて計算しています。○給気量: 換気扇の吹き出し口で測った風量○排気量: 換気扇の吸い込み口で測った風量AB 給気量、排気量について有効換気量の測定方法(JIS B8628)①試験室に本体、パイプ、外壁部材を取付け、CO2ガスを試験室内に注入する。②換気扇運転状態で試験室内のCO2濃度を測定する。③約30分後のCO2濃度の減衰具合から、換気扇の換気量(有効換気量)を算出します。同時給排気形の場合、換気扇内部や吹き出し口、吸い込み口周辺でおこるショートサーキットによる換気ロスが生じます。そのロス分を差し引いた実際の排気量をいいます。 有効換気量について試験室測定状態サンプリングパイプサンプリングパイプ外壁部材本体パイプ排気(EA)給気(SA)排気(RA)外気(OA)チャンパー内一部は室内に流れず排気されてしまう。排気給気ⒶⒷ【羽根径8㎝タイプ 表2】169パイプ用ファン

元のページ  ../index.html#170

このブックを見る