吸収冷温水機/吸収冷凍機2004年2月
14/40

12[TAG-E形]要項表形   名冷凍能力暖房能力出入口温度流量圧力損失接続口径パス数保有水量出入口温度流量圧力損失接続口径保有水量供給圧接続口径供給圧接続口径電源冷媒ポンプ溶液ポンプバーナファン電源容量配線サイズ伝熱面積煙道接続サイズTAG-EN015EEN018EEN021EEN025EEN028EEN032EEN036EEN040EEN045EEN050EN060EN070EN080EN090EN100EkW527 633 738 879985 1,125 1,266 1,407 1,582 1,758 2,110 2,461 2,813 3,165 3,516 {USRt}150 180 210 250 280320 360 400 450 500 600 700 800 900 1,000 kW410(474) 492(570)573(665)683(791) 765(886)874(1,013) 1,003(1,140) 1,114(1,266) 1,253(1,424) 1,393(1,583)1,8812,1952,2862,5712,857℃冷水12→7 温水55.6→60冷水12→7 温水56→60/min1,510 1,810 2,120 2,520 2,820 3,230 3,630 4,030 4,540 5,040 6,050 7,060 8,060 9,070 10,080kPa 858881847070717367676974737475{mAq }8.7 9 8.3 8.6 7.17.17.27.46.86.8 7.07.57.47.5 7.7A100 100 125 125 150 150 150 150 200 200 200 200 250 250 250 4 4 4 4 3 3 3 3 3 3 332 2 2 210 250 300 350 380 440 490 540 610 680 8209601,0101,1301,250℃32→37.532→38/min2,500 3,000 3,500 4,170 4,670 5,330 6,000 6,670 7,500 8,340 10,00011,67013,34015,00016,670kPa 113 123 118 123 93989898939888103 121123128{mAq }11.512.512.012.59.5 10.010.010.09.5 10.09.0 10.512.3 12.613.1A125 125 150 150 200 200 200 200 250 250 250 250 300 300 300 3 3 3 3 2 2 2 2 2 2 2 2 2 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 290 340 410 480 560 630 700 780 920 1,010 1,2101,4102,0302,2502,400kPa 1.51.51.51.58.88.88.88.88.88.88.88.814.714.714.7{mmAq}150 150 150 150 900 900 900 900 900 900 900 900 1,500 1,500 1,500 A100 100 100 125 8080808080808080808080Nm3/h 82.498.8 115.3 137.3 153.7175.7197.6219.6247.1274.5 378.4 441.5 504.6 567.6 630.7 Nm3/h 90.8(104.9)108.8(126.0)126.8(147.1)151.0(174.9) 169.2(196) 193.4(224) 221.8(252.1) 246.5(280.1) 277.3(315.1) 308(350)415.3 484.6 504.6 567.6 630.7 kPa 2.02.02.02.02.02.02.02.02.02.08.88.814.714.714.7{mmAq}200 200 200 200 200 200 200 200 200 200 900 900 1,500 1,500 1,500 A8080808080808080100 100 6580808080Nm3/h 33.740.447.256.262.971.980.989.8101.1112.3 154.8 180.6 206.4 232.2 258.0 Nm3/h 37.1(42.9)44.5(51.5)51.9(60.2)61.8(71.5)69.2(80.2)79.1(91.6)90.7(103.1) 100.8(114.6) 113.4(128.9) 126(143.2)169.9 198.2 206.4 232.2 258.0 V×Hz200V×50/60Hz 、220V×60HzkW0.150.150.3 0.3 0.3 0.3 0.4 0.4 0.4 0.4 0.4 0.4 0.40.40.4 kW2.2+0.552.2+0.552.2+0.753.2+0.753.2+1.53.2+1.53.2+1.53.7+1.53.7+1.53.7+1.55.5+0.755.5+0.755.5+0.755.5+0.755.5+0.75kW2.2 2.2 3.7 3.7 3.7 3.7 5.5 5.5 5.5 5.5 7.57.5 111111kVA 10.510.513.51516.516.51919.5222222.522.527.527.527.5mm25.5 5.5 8 8 1414222222222222383838m29.7 11.713.816.119.621.423.627.129.532.538.344.656.061.767.5mm350×310 450×370450×370 480×370 450×430480×430515×460568×460 550×515550×568 545×682692×667 669×704669×704786×704冷 温 水 系冷 却 水 系ガ  ス  仕  様電気仕様パス数4,500kcal/Nm311,000kcal/Nm3消費量冷房暖房吸収器凝縮器消費量冷房暖房注1)()内は暖房最大時の値です。注2)冷温水、冷却水の汚れ係数は0.000086m2K/W{0.0001m2h℃/kcal}としています。注3)バーナファン容量は燃焼量、ガス仕様により変わる可能性があります。詳細設計の際はお問い合わせ願います。注4)冷温水、冷却水の最高使用圧は0.78MPa(ゲージ圧){8kg/cm2}です。注5)性能、機能についてはJISB8622に基づきます。注6)幅寸法(W)はガス仕様により異なります。詳細寸法は外形図によりご確認願います。本値は13Aの場合の値です。(供給圧は要項表の値です。)注7)配線サイズは参考値です。()年間冷房運転時間2000H以下:N4000H以下:NL排ガス熱回収形39%省エネルギー形30%省エネルギー形

元のページ  ../index.html#14

このブックを見る