吸収冷温水機/吸収冷凍機2004年2月
21/40

19パック形吸収冷温水機【TAP形】形名冷房能力標準過大超過大能力制御方式冷水入口出口温度温水入口出口温度循環水量標準高揚程接続口径冷房時消費量暖房標準形暖房過大形超暖房過大形接続口径標準高揚程冷却水ポンプ定格出力冷却塔ファン定格出力電源容量消費電力(冷房)消費電力(暖房)電源容量消費電力(冷房)消費電力(暖房)電源容量消費電力(冷房)消費電力(暖房)電源容量消費電力(冷房)消費電力(暖房)電源容量消費電力(冷房)消費電力(暖房)電源容量消費電力(冷房)消費電力(暖房)冷温水器冷却塔運転質量冷温水器冷却塔運転質量冷温水器冷却塔運転質量暖房標準形暖房過大形超暖房過大形TAP-CG004(H,F)005(H,F)006(H,F)007(H,F)008(H,F)009(H,F)010(H,F)011(H,F)012(H,F)013(H,F)kW140.7 175.8 211.0 246.1 281.3 316.5 351.6 386.8 422.0 474.7 {USRT}405060708090100 110 120 135 kW112.9 141.2 169.3 197.7 225.8 254.0 282.2 310.5 338.6 380.9 kW140.7 175.8 211.0 246.2 281.4 316.5 351.6 386.9 422.0 474.8 kW172.1 215.1 225.8 300.0 344.2 387.2 430.2 464.5 506.4 569.8 準比例制御比例制御℃12.5→7 ℃暖房標準形:55.6→60、暖房過大形:54.5→60、超暖房過大形:53.3→60/min370 460 550 640 730 820 920 101011001240kPa 235 186/196 167/176 186/235 157/176 176/186 157/167 235/225 206/196 167/176 {mH2O}24.019/20 17/18 19/24 16/18 18/19 16/17 24/23 21/20 17/18 kPa 304/333 264/294 235/264 303/294 264/235 264/245 245/225 333/343 313 255/284 {mH2O}31/34 27/30 24/27 31/30 27/24 27/25 25/23 34/35 3226/29 A6565808080100 100 100 100 100 kW139.4 174.3 209.2 244.0 278.8 313.7 348.6 383.4 418.3 470.6 kW139.4 174.3 209.2 244.0 278.8 313.7 348.6 383.4 418.3 470.6 kW173.8 217.2 260.7 304.1 347.6 390.9 434.4 477.9 521.3 586.5 kW121.6 265.7 316.0 370.6 425.1 478.4 531.5 573.8 625.6 703.8 A40404040404040404040(注6)3相200V×50/60Hz kW3.7 3.7 3.7 5.5 5.5 5.5 5.5 7.5 7.5 7.5 kW5.5 5.5 5.5 7.5 7.5 7.5 7.5 111111kW2.2 3.7 3.7 3.7 3.7 5.5 5.5 5.5 5.5 7.5 kW1.5 1.5 2.2 2.2 3.7 3.7 5.5 3.7 5.5 5.5 kVA 17.320.621.622.724.627.529.730.933.235.4kW11.314.214.915.817.319.921.723.024.826.5kW6.4 6.8 6.9 8.5 8.5 9.0 9.0 12.112.112.1kVA 19.222.623.625.026.929.832.035.737.940.2kW12.915.816.517.619.121.723.526.828.630.4kW8.0 8.3 8.5 10.310.310.910.916.016.016.0kVA 17.420.921.623.225.027.530.530.933.235.4kW11.514.414.916.417.919.922.423.024.826.5kW6.6 6.9 6.9 9.0 9.0 9.0 9.7 12.112.112.1kVA 19.422.923.625.427.329.832.735.737.940.2kW13.115.916.518.219.721.724.226.828.630.4kW8.2 8.5 8.5 10.910.910.911.616.016.016.0kVA 17.720.921.623.225.828.230.530.933.235.4kW11.814.414.916.418.620.622.423.024.826.5kW6.9 6.9 6.9 9.0 9.7 9.7 9.7 12.112.112.1kVA 19.722.923.625.428.030.532.735.737.940.2kW13.415.916.518.220.422.424.226.828.630.4kW8.5 8.5 8.5 10.911.611.611.616.016.016.0kg3350345038004500455051405150564057006200kg520 600 620 720 730 830 850 119012901410kg4570488053306310642072207280814087909350kg3350345038004500455051405150564057006200kg520 600 620 720 730 830 850 119012901410kg4570488053306310642072207280814087909350kg3450360039904600460053205330570057606350kg520 600 620 720 730 830 850 119012901410kg4650503054306410647074007460820588509500m24.1 4.1 4.7 6.3 6.3 7.1 7.1 8.6 8.6 9.9 m24.1 4.1 4.7 6.3 6.3 7.1 7.1 8.6 8.6 9.9 m24.1 4.7 5.7 7.1 7.1 8.6 8.6 9.9 9.9 11.7[TAP-CG形](40USRt~135USRt)パック標準形・暖房過大形・暖房超過大形要項表(ガス焚)暖房能力冷温水ポンプ機外揚程冷却水ポンプ定格出力搬入質量搬入質量搬入質量伝熱面積冷温水系ガ ス電 気暖房標準標準揚程高揚程標準揚程高揚程標準揚程高揚程標 準過 大超過大暖房過大暖房超過大質 量暖房時消費量注1)ガスの供給圧力は、低圧供給です。(3.5kPa以下)注2)ガス消費量は高位発熱量であらわしています。使用ガスの高位発熱量で割ると1時間あたりのガスの使用量が求められます。注3)冷温水系、冷却水系の最高使用圧は0.58Mpa(ゲージ圧){6kg/cm2}です。注4)冷温水系、冷却水系のスケール係数は0.086m2K/kW{0.0001m2h℃/kcal}です。注5)性能はJIS B 8622に準拠します。注6)ガス接続口径は13Aの場合です。また013Fの場合の口径は50Aとなります。注7)冷温水ポンプの機外揚程の□/□は50Hz/60Hz の値を示します。

元のページ  ../index.html#21

このブックを見る