吸収冷温水機/吸収冷凍機2004年2月
22/40

[TAK-CK形](40USRt~135USRt)パック標準形・暖房過大形・暖房超過大形要項表(灯油焚)20形名冷房能力標準過大超過大能力制御方式冷水入口出口温度温水入口出口温度循環水量標準高揚程接続口径冷房時消費量暖房標準形暖房過大形超暖房過大形標準高揚程冷却水ポンプ定格出力冷却塔ファン定格出力電源容量消費電力(冷房)消費電力(暖房)電源容量消費電力(冷房)消費電力(暖房)電源容量消費電力(冷房)消費電力(暖房)電源容量消費電力(冷房)消費電力(暖房)電源容量消費電力(冷房)消費電力(暖房)電源容量消費電力(冷房)消費電力(暖房)冷温水器冷却塔運転質量冷温水器冷却塔運転質量冷温水器冷却塔運転質量暖房標準形暖房過大形超暖房過大形暖房能力冷温水ポンプ機外揚程冷却水ポンプ定格出力搬入質量搬入質量搬入質量伝熱面積冷温水系灯 油電 気暖房標準標準揚程高揚程標準揚程高揚程標準揚程高揚程標 準過 大超過大暖房過大暖房超過大質 量消費量TAP-CK004(H,F)005(H,F)006(H,F)007(H,F)008(H,F)009(H,F)010(H,F)011(H,F)012(H,F)013(H,F)kW140.7175.8211.0246.1281.3316.5351.6386.8422.0474.7{USRT}405060708090100110120135kW112.9141.2169.3197.7225.8254.0282.2310.5338.6380.9{kcal/h}97,100121,400145,600170,000194,200218,400242,700267,000291,200327,600kW140.7175.8211.0246.2281.4316.5351.6386.9422.0474.8{kcal/h}121,000151,200181,500211,700242,000272,200302,400332,700362,900408,300kW172.1215.1225.8300.0344.2387.2430.2464.5506.4569.8{kcal/h}148,000185,000220,000258,000296,000333,000370,000399,500435,500490,000Hi-Lo-OFF℃12.5→7℃暖房標準形:55.6→60、暖房過大形:54.5→60、超暖房過大形:53.3→60/min370460550640730820920101011001240kPa235186/196167/176186/235157/176176/186157/167235/225206/196167/176{mH2O}2419/2017/1819/2416/1818/1916/1724/2321/2017/18kPa304/333264/294235/264303/294264/235264/245245/225333/343313255/284{mH2O}31/3427/3024/2731/3027/2427/2525/2334/353226/29A6565808080100100100100100/h13.016.219.422.725.929.232.435.638.943.7/h13.016.219.422.725.929.232.435.638.943.7/h16.220.224.228.332.336.340.444.448.454.5/h19.824.729.434.439.544.549.453.358.165.43相200V×50/60Hz kW3.7 3.7 3.7 5.5 5.5 5.5 5.5 7.5 7.5 7.5 kW5.5 5.5 5.5 7.5 7.5 7.5 7.5 111111kW2.2 3.7 3.7 3.7 3.7 5.5 5.5 5.5 5.5 7.5 kW1.5 1.5 2.2 2.2 3.7 3.7 5.5 3.7 5.5 5.5 kVA 17.620.821.522.724.627.130.530.933.235.4kW11.514.114.616.017.519.522.423.024.826.5kW6.6 6.6 6.6 8.7 8.7 8.7 9.7 12.112.112.1kVA 19.522.723.425.026.929.432.735.737.940.2kW13.115.616.217.919.421.424.226.828.630.4kW8.2 8.2 8.2 10.510.510.511.616.016.016.0kVA 17.620.821.622.725.828.230.530.933.235.4kW11.514.115.116.018.620.622.423.024.826.5kW6.6 6.6 7.1 8.7 9.7 9.7 9.7 12.112.112.1kVA 19.522.723.625.028.030.532.735.737.940.2kW13.115.616.717.920.422.424.226.828.630.4kW8.2 8.2 8.7 10.511.611.611.616.016.016.0kVA 17.720.921.623.925.828.230.530.933.235.4kW12.014.615.117.118.620.622.423.024.826.5kW7.1 7.1 7.1 9.7 9.7 9.7 9.7 12.112.112.1kVA 19.722.923.626.228.030.532.735.737.940.2kW13.616.116.718.920.422.424.226.828.630.4kW8.7 8.7 8.7 11.611.611.611.616.016.016.0kg3350345038004500455051405150564057006200kg520 600 620 720 730 830 850 119012901410kg4570488053306310642072207280814087909350kg3350345038004500455051405150564057006200kg520 600 620 720 730 830 850 119012901410kg4570488053306310642072207280814087909350kg3450360039904600460053205330570057606350kg520 600 620 720 730 830 850 119012901410kg4650503054306410647074007460820588509500m24.1 4.1 4.7 6.3 6.3 7.1 7.1 8.6 8.6 9.9 m24.1 4.1 4.7 6.3 6.3 7.1 7.1 8.6 8.6 9.9 m24.1 4.7 5.7 7.1 7.1 8.6 8.6 9.9 9.9 11.7注1)灯油の発熱量3.48kJ/、比重0.8g/cm2とします。注2)冷温水系、冷却水系の最高使用圧は0.58Mpa(ゲージ圧){6kg/cm2}です。注3)冷温水系、冷却水系のスケール係数は0.086m2K/kW{0.0001m2h℃/kcal}です。注4)性能はJIS B 8622に準拠します。注5)冷温水ポンプの機外揚程の□/□は50Hz/60Hzの値を示します。注6)NOx 値は、灯油の場合100ppm(O2=0%換算値)程度です。

元のページ  ../index.html#22

このブックを見る