クーリングタワー2007年6月
13/43

ターボ冷凍機等あらゆる循環水の冷却に一般用■形式選定表・標準仕様・音響値RTC-1008U~10008U(超低騒音形) 温度条件37℃→32℃1008U1258U1508U1758U2008U2258U2508U3008U3508U4008U5008U6008U7008U8008U10008U296529653335333533353485366036603950425046504710511052955695290029003300330033003700440044004800558055806600660076007600487516506562562625510510579751751749749957957125125150150150150200200200250250250250300300505080808080100100100100100125125150150505080808080100100100100100125125150150202025252525253240405050508080202025252525253240405050508080150015001800180018002100240024002400300030003400340036003600700760980101010501160157016501900319036104470495058206420158016402210224022802720378038704260609065108820930012120127201127.51413.41700.71971.92270.72552.82811.03407.23970.34528.45753.76808.78033.69078.211468.81300.01625.01950.02275.02600.02925.03250.03900.04550.05200.06500.07800.09100.010400.013000.01767.32183.62620.33049.33270.63876.44443.85206.46106.67010.08422.610463.811856.913951.716872.062.564656666.566.566.56767.57070727272.57356.557.55959.560.561626363.566676868.570.57144454747.548.549.5515252.55656.558.55960.5612.23.73.75.55.55.55.55.57.5111115152222444446666666688125125150150150150200200200250250250250300300外形寸法〔mm〕接続配管〔A〕モータファン循環水量〔L/min〕騒音値dB(A)質 量〔kg〕HD*aInOutOvDφ〔mm〕28℃WB27℃WB24℃WBファン45°Df点DrAuMa製品質量運転質量2m点16m点kWP形式RTC-項目RTC-1008N~10008N(低騒音形) 温度条件37℃→32℃1008N1258N1508N1758N2008N2258N2508N3008N3508N4008N5008N6008N7008N8008N10008N29652965333533353335343536603660395042504650471051105295569529002900330033003300370044004400480055805580660066007600760038741640646246247747247251070770782282279179112512515015015015020020020025025025025030030050508080808010010010010010012512515015050508080808010010010010010012512515015020202525252525324040505050808020202525252525324040505050808015001500180018001800180024002400240030003000340034003600360069074095098010301080153016101790294033704260474052405910157016202180221022602640374038304140584062708610909011540122101127.51413.41700.71971.92270.72552.82811.03407.23956.94528.45753.76808.78033.69078.211468.81300.01625.01950.02275.02600.02925.03250.03900.04550.05200.06500.07800.09100.010400.013000.01767.32183.62620.33049.33270.63876.44443.85206.46143.87010.08422.610463.811856.913951.716872.06667.568.570.5717174.5757677.578.57777.578.57960.561.56364.565.5656868.57071.57272737474.547.5495152.5535357.5586062636363.56565.52.23.73.75.55.55.55.55.57.5111115152222444444444446666125125150150150150200200200250250250250300300外形寸法〔mm〕接続配管〔A〕モータファン循環水量〔L/min〕騒音値dB(A)質 量〔kg〕HD*aInOutOvDφ〔mm〕28℃WB27℃WB24℃WBファン45°Df点DrAuMa製品質量運転質量2m点16m点kWP形式RTC-項目RTC-1008~5008(標準形) 温度条件37℃→32℃10081258150817582008225825083008350840085008296529653335333533353435366036603950425046502900290033003300330037004400440048005580558038741640646246247747247251070770712512515015015015020020020025025050508080808010010010010010050508080808010010010010010020202525252525324040502020252525252532404050150015001800180018001800240024002400300030006807309409701020107015201600177029203340156016102170220022502630373038204120582062401127.51413.41700.71971.92270.72552.82811.03407.23956.94528.45753.71300.01625.01950.02275.02600.02925.03250.03900.04550.05200.06500.01767.32183.62620.33049.33270.63876.44443.85206.46143.87010.08422.67879.58080.58080.577777880.58170.5717273.574.574.57373.5747575.558.559.561626262.562626365.5662.23.73.75.55.55.55.55.57.5111144444444444125125150150150150200200200250250外形寸法〔mm〕接続配管〔A〕モータファン循環水量〔L/min〕騒音値dB(A)質 量〔kg〕HD*aInOutOvDφ〔mm〕28℃WB27℃WB24℃WBファン45°Df点DrAuMa製品質量運転質量2m点16m点kWP形式RTC-項目● H:塔高(モータを含まず) D:最大外径 In:循環水入口 Out:循環水出口 Ov:オーバフロー Dr:ドレン Au:自動給水口 Ma:手動給水口● 冷凍能力は循環水量13L/min・4.535kW 外気湿球温度27℃ 入口水温度37℃ 出口水温度32℃の場合が設計基準です。● 5.5kW以上のモーターには、スターデルタ起動装置の取付けをお勧めいたします。● 音響値は十分空間をもたせた反射音及び暗騒音の影響の無い場所での測定値であり、設定条件等により本表と異なる場合があります。● 塔循環水圧力損失は、塔高Hを見込んで下さい。● 接続配管のIn及びOutはJIS 10Kフランジその他は管用ネジ(Rc及びRp)を使用しております。● *aはモータ概略寸法ですので、詳細については、弊社営業担当までお問い合わせください。12

元のページ  ../index.html#13

このブックを見る